Document Library for WPF | ComponentOne
C1.WPF.Document.4.6.2 Assembly / GrapeCity.Documents.Imaging.jpeg.jj2000.j2k.quantization.dequantizer Namespace / StdDequantizerParams Class
Fields Methods


In This Topic
    StdDequantizerParams Class Members
    In This Topic

    The following tables list the members exposed by StdDequantizerParams.

    Public Constructors
    Public Fields
     NameDescription
    Public FieldThe quantization step "exponent" value, for each resolution level and subband, as it appears in the codestream. The first index is the resolution level, and the second the subband index (within the resolution level), as specified in the Subband class. When in derived quantization mode only the first resolution level (level 0) appears.

    For non-reversible systems this value corresponds to ceil(log2(D')), where D' is the quantization step size normalized to data of a dynamic range of 1. The true quantization step size is (2^R)*D', where R is ceil(log2(dr)), where 'dr' is the dynamic range of the subband samples, in the corresponding subband.

    For reversible systems the exponent value in 'exp' is used to determine the number of magnitude bits in the quantized coefficients. It is, in fact, the dynamic range of the subband data.

    In general the index of the first subband in a resolution level is not 0. The exponents appear, within each resolution level, at their subband index, and not in the subband order starting from 0. For instance, resolution level 3, the first subband has the index 16, then the exponent of the subband is exp[3][16], not exp[3][0].

     
    Public FieldThe quantization step for non-reversible systems, normalized to a dynamic range of 1, for each resolution level and subband, as derived from the exponent-mantissa representation in the codestream. The first index is the resolution level, and the second the subband index (within the resolution level), as specified in the Subband class. When in derived quantization mode only the first resolution level (level 0) appears.

    The true step size D is obtained as follows: D=(2^R)*D', where 'R=ceil(log2(dr))' and 'dr' is the dynamic range of the subband samples, in the corresponding subband.

    This value is 'null' for reversible systems (i.e. there is no true quantization, 'D' is always 1).

    In general the index of the first subband in a resolution level is not 0. The steps appear, within each resolution level, at their subband index, and not in the subband order starting from 0. For instance, if resolution level 3, the first subband has the index 16, then the step of the subband is nStep[3][16], not nStep[3][0].

     
    Top
    Public Methods
     NameDescription
    Public MethodOverridden. Returns the type of the dequantizer for which the parameters are. The types are defined in the Dequantizer class.  
    Top
    See Also

    Reference

    StdDequantizerParams Class
    GrapeCity.Documents.Imaging.jpeg.jj2000.j2k.quantization.dequantizer Namespace
    GrapeCity.Documents.Imaging.jpeg.jj2000.j2k.quantization.dequantizer.StdDequantizer